Description of Adash 3600-MPX
The Adash 3600-MPX module serves to connect up to 8 sensors with ICP supply to the Adash
3600-MAIN module. The original one-channel basic set Adash 3600 thus becomes multi-channel and
enables cyclic measurement on all the mounted measurement channels, if extended with this
module.
The maximum number of the Adash 3600-MPX extending modules to the Adash 3600 system is 8,
therefore the basic Adash 3600 set can extended from one to a maximum of 64 measured channels.
Description of Module Control
On the front panel there are all the control and display elements of the Adash 3600-MPX module.
Fig. Front panel of the Adash 3600-MPX module
Mode Button
To select the mode of channel number display (at the Adash 3600-MPX module) and measured
value display (at the Adash 3600-MAIN module). The selected mode is indicated by a green indicator
located under the Mode button.
Selected mode Manner of display
--------------------------------------------------------------------------------------------------------------------------------------
ALL it displays cyclically the state of all the measured channels,
MAX it displays the state of the channel with the highest vibrations in compliance with ISO,
USER it displays continuously the state of the selected channel.
By keeping the Mode button pushed for approx. 3 seconds, the automatic channel switching during
measurement is blocked and all the three indicators of the displayed mode on the front panel switch
on. Use this option if an external analyser is connected to the Adash 3600 system. In this mode
channels can be switched only by pushing the Channel button and the Adash 3600-MAIN module
measures only the selected channel.
With the displayed channel number the decimal point is shown.
Channel Button
It enables to select the displayed (not measured) channel.
- If modes ALL or MAX are selected, values measured at the selected channel (vibration
sensor) appear after pushing the Channel button at the Adash 3600-MAIN module for approx. 20
seconds.